Product Details
Place of Origin: China
Brand Name: Senova
Certification: CE
Model Number: NuOven FC624-I
Payment & Shipping Terms
Minimum Order Quantity: 1 unit
Price: Available upon request
Packaging Details: Carton with pallet
Delivery Time: Approx. 10 working days
Payment Terms: T/T
Supply Ability: 500 units/month
| Model | NuOven FB31-I | NuOven FB72-I | NuOven FB136-I | NuOven FB252-I | NuOven FB429-I | NuOven FB624-I | |
| NuOven FC31-I(*Note) | NuOven FC72-I(*Note) | NuOven FC136-I(*Note) | NuOven FC252-I(*Note) | NuOven FC429-I(*Note) | NuOven FC624-I(*Note) | ||
| Chamber volume(L) | 32 | 72 | 136 | 225 | 430 | 624 | |
| Convection Method | Vertical Forced Convection (Fan) | ||||||
| Temp. Control Range | RT+10℃~ 200℃ | ||||||
| Temperature | Accuracy | ± 1℃ at 100℃ | |||||
| Fluctuation | ± 1℃ | ||||||
| Uniformity | ± 1℃ at 100℃ | ± 2℃ at 100℃ | ± 2.5℃ at 100℃ | ||||
| Controller | PID microprocessor control, soft touch, LED display | ||||||
| Sensor | Pt 100 resistor | ||||||
| Timer | Power-on, power off and working. Timing range: 1min-99hr | ||||||
| Material | Internal | 304 stainless steel working chamber | |||||
| External | Steel (powder coating) | ||||||
| Dimensions (WxDxH,mm) | Internal | 300*300*350 | 400*400*450 | 450*550*550 | 500*600*750 | 600*550*1300 | 800*600*1300 |
| External | 445*450*710 | 550*550*800 | 640*700*900 | 690*730*1100 | 770*710*1750 | 970*760*1750 | |
| Net Weight(Kg) | 36 | 50 | 71.5 | 90 | 183 | 250 | |
| Consumption Power (W) | 1050 | 1350 | 1890 | 2500 | 4500 | 5700 | |
| Shelf Size(mm) | 293*275 | 393*375 | 443*530 | 493*580 | 590*514 | 790*564 | |
| Shelf Qty(Standard/Max.) | 2/4 | 2/4 | 2/4 | 2/5 | 3/6 | 3/6 | |
| Power Supply | 220V/50Hz (Optional: 220V/60Hz, 110V/60Hz) | ||||||
NuOven FC—Series have10-segment temperature control program to realize temperature curve program running.
For laboratories working with sophisticated, temperature-sensitive materials, a standard drying oven can be destructive. Vacuum ovens solve this problem by integrating a vacuum pump with a heating chamber. By reducing the internal air pressure, the boiling point of liquids within a sample is dramatically lowered. This allows moisture or solvents to be removed at temperatures far below their normal boiling points, sometimes at room temperature or slightly above.
This technique is indispensable for drying delicate biological preparations, purifying heat-labile chemicals, removing entrapped gases from composites, or gently drying electronic components. It prevents oxidation, thermal cracking, and decomposition, preserving the sample's intrinsic properties while still achieving the desired dry state.