SENOVA BIOTECH (SHANGHAI) CO., LTD.
SENOVA BIOTECH (SHANGHAI) CO., LTD.
Products
Home /

Products

Type I / Type III Laboratory Water Purification System TopPure30A-I

Product Details

Place of Origin: China

Brand Name: Senova

Certification: CE

Model Number: TopPure30A-I

Payment & Shipping Terms

Minimum Order Quantity: 1 unit

Price: Available upon request

Packaging Details: plywood case

Delivery Time: 5-20 working days

Payment Terms: T/T

Supply Ability: 200 units

Get Best Price
Chat Now
Specifications
Highlight:

Class I laboratory water purification system

,

Class III ultrapure water system

,

TopPure30A-I lab water purifier

Product:
Laboratory Water Purification System
Pure Water Output:
30L/h
Feed Water:
Tap Water
Ultrapure Water Quality:
Resistivity 18.2MΩ .cm@25℃
Water Purity Level:
18.2 MΩ·cm
Output Water Quality:
Class I And III
Warranty:
1 Year
Input Voltage:
220V/50Hz,110V/60Hz
Product:
Laboratory Water Purification System
Pure Water Output:
30L/h
Feed Water:
Tap Water
Ultrapure Water Quality:
Resistivity 18.2MΩ .cm@25℃
Water Purity Level:
18.2 MΩ·cm
Output Water Quality:
Class I And III
Warranty:
1 Year
Input Voltage:
220V/50Hz,110V/60Hz
Description
Type I / Type III Laboratory Water Purification System TopPure30A-I
Type I , Type III Laboratory Water Purification System TopPure30A-I
Features
  1. Our Laboratory Purification System is engineered to deliver consistent, high-purity water for critical applications.
  2. The robust Pretreatment Cartridge employs a compression molding process, effectively eliminating water leakage risks.
  3. Integrated active carbon within pretreatment removes free chlorine from tap water comprehensively.
  4. Built-in PP cotton filtration captures particulates and sediments at the initial stage.
  5. The innovative Reverse Osmosis Module features a low-restriction design, significantly extending its operational lifespan.
  6. Automated forward and backward rinse cycles clean the RO membrane surface, ensuring stable performance and durability.
  7. A dual-wavelength UV lamp, housed in a corrosion-resistant stainless steel chamber, provides powerful purification.
  8. The UV lamp utilizes a high-transmittance synthetic quartz sleeve for maximum efficiency.
  9. Smart activation ensures the UV lamp operates only during ultrapure water production, saving energy.
  10. The Purification Cartridge system is equipped with high-quality, precision-grade ion exchange resin.
  11. A dual-column design vastly increases ion exchange capacity and reduces long-term running costs.
  12. An integrated ultra-purification cartridge targets trace-level ionic and organic contaminants.
  13. A high-quality nuclear-grade resin polishing cartridge delivers the final purity polish.
  14. An active carbon supplement within the cartridge effectively controls organic levels.
  15. The Ultra-Filtration/Micro Filter effectively removes endotoxins, nucleases, and proteins, vital for cell culture.
  16. Filter heads allow easy switching to alternative microfilters for diverse application needs.
  17. A final Point-Of-Use 0.22µm membrane filter ensures contaminant-free dispensing.
  18. Microprocessor Control with PIN-code access protects system settings and protocols.
  19. A fully automatic self-diagnostic system continuously monitors all operational parameters.
  20. Comprehensive Sanitization automates disinfection of the entire fluid pathway.
  21. Module-designed Cartridges enable tool-free, quick-change replacements to minimize downtime.
  22. A high-precision, flow-through resistivity meter with a 0.01 cm⁻¹ cell constant provides unparalleled accuracy.
  23. Automatic Temperature Compensation (0.1°C resolution) delivers meaningful, real-time resistivity readings.
  24. A large, easy-to-read LCD display shows conductivity, resistivity, tank levels, and consumable life.
  25. Contamination-free 30L/60L PE tanks with low extractables include level sensors and overflow protection.
  26. An RS232 port enables seamless network integration and remote monitoring.
  27. An optional strengthened pretreatment module with a 20-inch detergent cartridge handles challenging feed water.
  28. The system boasts a premium touch-screen interface for intuitive operation.
  29. Online TOC monitoring is available to prevent organic breakthrough proactively.
  30. Remote water dispenser options allow convenient water collection and system status checks.
Configuration
TopPure-Series TopPure30A-I
Pretreatment module
High pressure pump
Reverse osmosis
Dual wavelength UV-lamp
Ultra-purification cartridge
Ultrafiltration cartridge
EDI Module /
Point-of-use filter
Storage tank 30L
Air filter net for tank
UV-lamp sterilizer for water tank
Remote water dispenser with color display
TOC monitoring module /
Specifications
Model TopPure30A-I
Feed Water Requirement
Source Tap water
Conductivity* <2000us/cm
Hardness** <450ppm as CaCO3
Pressure 0.05~0.5MPa(7-72psi)
Temperature 5~40℃
Purification Water(Class III)
Ionic Rejection >95%
Bacteria Rejection >99%
Conductivity 1~20us/cm
Productivity Rate 30L/h
High Quality Purification Water(Type II)
Resistivity At 25℃ /
TOC / 
Dissolved Organic / 
Productivity Rate / 
Ultrapurification Water(Class I)
Resistivity At 25℃ 18.2MΩ.cm
Conductivity At 25℃ 0.055us/cm
TOC Level** 1~5ppb
Endotoxin(Pyrogens)**** <0.001EU/ml
Particulate(≥0.02µm) <1pc/ml
Bacteria* <0.1 cfu/ml
Rnase / Dnase** Free
Manual dispense flow rate 1.5~2.0L/min
Automatic dispense volume 100~60000ml
Electrical Requirements
Electrical Voltage 110V/220V±10%
Electrical Frequency 50HZ/60HZ
Packing Information
Net Weight
Main units 34kg
Water tank (30L) 7kg
External Dimensions(WxDxH)
Main units 315x525x570mm
Water tank (30L) 380x380x595mm
Shipping weight
Main units 37kg
Water tank (30L) 15kg
Shipping Dimensions(WxDxH)
Main units 525x610x770mm
Water tank (30L) 520x440x615mm
Introduction about laboratory water purification system

The consistent performance of a water purification system depends on a regular and proactive maintenance regimen. Pre-filters and carbon filters require periodic replacement to protect downstream components. RO membranes need monitoring for fouling. DI resins exhaust over time and must be regenerated or replaced. UV lamps lose intensity and should be changed annually. Adhering to the manufacturer’s maintenance schedule is crucial. Neglect can lead to a gradual decline in water quality, increased operating costs, and ultimately system failure, compromising the laboratory’s water supply.

Send your inquiry
Please send us your request and we will reply to you as soon as possible.
Send