Specifications
Highlight:

Type I Ultrapure Water Purification System

,

Type II Ultrapure Water Purification System

,

Water Purification System For Laboratory Use

Product:
Pure Water Ultra Pure Water System For Lab
Applications:
HPLC, Lab Water Needs
Feed Water Type:
<400μS/cm @25℃
Water Tank Storage:
30L
Disinfection Method:
UV Lamp Sterilization
Control System:
Touch Screen
Power Consumption (W):
120x2
Power Supply:
110V/220V±10%,50/60Hz
Product:
Pure Water Ultra Pure Water System For Lab
Applications:
HPLC, Lab Water Needs
Feed Water Type:
<400μS/cm @25℃
Water Tank Storage:
30L
Disinfection Method:
UV Lamp Sterilization
Control System:
Touch Screen
Power Consumption (W):
120x2
Power Supply:
110V/220V±10%,50/60Hz
Description
Type I II III Ultrapure Water Purification System For Laboratory Use
Type I II III RO / Pure / Ultra Pure Water System TopPure15D-ETD2 with TOC Monitoring

The industry's most complete water purification solution for highly regulated applications.
When your application requires the ultimate in water purity, this product provides the perfect solution. Consistently delivering water purity of 18.2MΩ.cm and underpinned by the advanced technologies, this model enables you to focus on attaining accurate results while ensuring an uninterrupted work flow.

Features
  1. Our system is engineered for economic efficiency, minimizing the total cost of ownership without compromising quality.
  2. The durable Pretreatment Cartridge with its leak-resistant design prevents costly water damage and component loss.
  3. Integrated active carbon and PP cotton protect expensive downstream modules, extending their service life.
  4. The Reverse Osmosis Module’s low-restriction design reduces pump energy consumption and wear.
  5. Automated membrane rinsing maximizes RO membrane lifespan, delaying major replacement costs.
  6. The intelligent UV lamp operates only during water production, conserving energy and lamp life.
  7. The revolutionary dual-column Purification Cartridge design dramatically increases ion exchange capacity.
  8. This high-capacity design directly minimizes consumable change frequency, reducing long-term running costs.
  9. By combining multiple purification stages into efficient cartridges, replacement labor and downtime are minimized.
  10. The active carbon supplement within the cartridge controls organics, protecting the resin and optimizing its use.
  11. The easy-switch capability of the Ultra-Filtration Filter allows selection of the most cost-effective filter for the task.
  12. Proactive system monitoring via the self-diagnostic function prevents small issues from becoming costly failures.
  13. PIN-code access prevents unauthorized use or setting changes that could waste water, energy, or consumables.
  14. Comprehensive Sanitization is automated, ensuring efficiency and repeatability while saving manual labor time.
  15. The quick-connect, Module-designed Cartridges make replacement a swift, tool-free task, saving technician time.
  16. High-precision resistivity monitoring ensures water is only used when it meets specification, preventing waste.
  17. Consumable life reminders on the LCD enable planned, bulk purchases and avoid emergency replacement premiums.
  18. The contamination-free PE tanks are durable and resistant to degradation, avoiding premature tank replacement.
  19. Overflow protection and level sensors prevent water loss and potential lab damage.
  20. The optional strengthened pretreatment module protects the entire system in harsh conditions, avoiding premature failure.
  21. The reliable, robust construction of all components minimizes unexpected breakdowns and service calls.
  22. Network compatibility allows for centralized monitoring of multiple systems, optimizing service schedules.
  23. The intuitive touch screen interface reduces training costs and operator errors that lead to waste.
  24. Optional online TOC monitoring can precisely predict resin exhaustion, allowing optimal change-out timing.
  25. The system's high recovery rate (inherent in the RO design) means less feed water is wasted as drain.
  26. Designed for easy maintenance, service tasks require minimal specialized tools or training.
  27. The overall system reliability translates to consistent water supply, preventing costly experimental delays.
  28. Investing in this system is an investment in predictable budgeting and reduced operational overhead for years to come.
Configuration
TopPure15D-Series TopPure15D-ETD2
Pretreatment module
High pressure pump
Reverse osmosis
Dual wavelength UV-lamp
Ultra-purification cartridge
Ultrafiltration cartridge
EDI Module
Point-of-use filter
Storage tank 30L
Air filter net for tank
UV-lamp sterilizer for water tank
Remote water dispenser with color display
TOC monitoring module
Specifications
Feed water requirement Conductivity μS/cm@25℃ <400
Pressure Mpa 0.1~0.4
Temperature ℃ 5~40
Pure water Ion rejection rate %@25℃ ≥95
Bacteria remove % >99
Make rate* L/H@25℃ 30
High-Pure water resistivity MΩ.cm >10
TOC** ppb <50
Micro-organisms CFU/ml ≤1
Particles(0.22μm)/ml <1
Make rate L/H 15
Dispensing rate L/H >60
Ultra-Pure water resistivity MΩ.cm >18
TOC ppb 1-10
Endotoxin Eu/ml <0.001
Particles***(0.22μm) /ml <1
Dispensing rate L/H 60-100
Other Power Consumption W 120×2
Weight kg 90
Storage tank 30L
Main System dimensions(W×D×H,mm) 525×314×571
Storage Tank dimensions(W×D×H,mm) 430×380×580
water dispenser dimensions(W×D×H,mm) 585×410×260
Introduction about laboratory water purification system

The selection of water grade is application-driven. Type III/RO water is adequate for water baths, humidifiers, and preliminary rinsing. Type II water is the standard for clinical analyzers, microbiological media preparation, and general chemistry. Type I ultrapure water is non-negotiable for trace element analysis (AAS, ICP-MS), ion chromatography, and all molecular biology work involving DNA, RNA, or proteins. Matching the water to the task ensures accuracy without incurring unnecessary cost or accelerating the depletion of high-purity components like DI resins.