SENOVA BIOTECH (SHANGHAI) CO., LTD.
SENOVA BIOTECH (SHANGHAI) CO., LTD.
Products
Home /

Products

Ultrapure Laboratory Water Purification System 30L/H Lab Water Purification

Product Details

Place of Origin: China

Brand Name: Senova

Certification: CE

Model Number: TopPure15B-E1

Payment & Shipping Terms

Minimum Order Quantity: 1 unit

Price: Available upon request

Packaging Details: plywood case

Delivery Time: 5-20 working days

Payment Terms: T/T

Supply Ability: 100 units

Get Best Price
Chat Now
Specifications
Highlight:

Ultrapure Laboratory Water Purification System

,

Laboratory Water Purification System 30L/H

,

30L/H Lab Water Purification

Type:
Water Purification System
Water Requirement:
Tap Water(TDS<<2000us/cm)
Production Capacity:
30 L/hour (Type III),15 L/hour (Type I)
Dispense Volume:
100-60000ml
Water Tank Capacity:
30 L
Control System:
Touch Screen
Applications:
Molecular Biology, Cell Culture, Analytical Chemistry, Clinical Laboratories
Power Supply:
AC220V-240V / 50-60Hz,110V/60Hz
Type:
Water Purification System
Water Requirement:
Tap Water(TDS<<2000us/cm)
Production Capacity:
30 L/hour (Type III),15 L/hour (Type I)
Dispense Volume:
100-60000ml
Water Tank Capacity:
30 L
Control System:
Touch Screen
Applications:
Molecular Biology, Cell Culture, Analytical Chemistry, Clinical Laboratories
Power Supply:
AC220V-240V / 50-60Hz,110V/60Hz
Description
Ultrapure Laboratory Water Purification System 30L/H Lab Water Purification
RO (Type I) / Pure (Type II) / Ultra Pure (Type III) Laboratory Water System TopPure15B-E1
  1. This system sets the scientific standard for producing reagent-grade water with exceptional consistency.
  2. Precision-engineered Pretreatment ensures feed water is meticulously prepared for primary purification.
  3. The compression-molded cartridge eliminates leakage, a critical variable in maintaining a pure environment.
  4. Complete chlorine removal by integrated active carbon is non-negotiable for protecting sensitive RO membranes.
  5. The Reverse Osmosis Module’s low-restriction design is calibrated for optimal recovery and salt rejection.
  6. Its automated rinse function is precisely timed to maintain membrane surface integrity and performance.
  7. Purification achieves trace-level excellence via a multi-stage cartridge system.
  8. High-quality precision-grade resin initiates high-capacity deionization.
  9. The dual-column design is a calculated approach to maximize resin utilization and efficiency.
  10. An ultra-purification cartridge targets the faintest ionic residues.
  11. Final polishing with nuclear-grade resin seeks and removes contaminants to parts-per-trillion levels.
  12. Integrated active carbon meticulously suppresses organic concentrations within the purification zone.
  13. For the most demanding applications, the Ultra-Filtration Filter provides precision removal of biomolecules.
  14. The option to switch microfilters allows scientists to tailor the final purification step to their exact protocol.
  15. The ultimate precision filter, the 0.22μm Point-Of-Use membrane, is the final gatekeeper at dispensing.
  16. Precision monitoring is achieved via a microprocessor with PIN-protected calibration and settings.
  17. Automated diagnostics provide precise, real-time data on every system component.
  18. Precision sanitization is guaranteed as the automated process covers every wetted surface.
  19. The high-precision resistivity meter is the cornerstone of accurate water quality verification.
  20. Its flow-through design and ultra-low cell constant (0.01 cm⁻¹) are purpose-built for low-ionic measurement.
  21. Automatic Temperature Compensation with 0.1°C resolution ensures readings are scientifically meaningful.
  22. Water quality data is presented with clarity on a high-resolution LCD display.
  23. Reservoir levels are monitored precisely to ensure uninterrupted supply.
  24. Low-extractables tanks are precision-molded to prevent the introduction of interfering compounds.
  25. Data output via RS232 allows for precise logging and analysis of water quality trends.
  26. Precision organic monitoring is available through the online TOC option.
  27. The system enables precision water delivery, with remote dispenser options for cleanroom or bench use.
  28. Every feature is designed to deliver water that meets the precise requirements of modern analytical science.
Configuration
TopPure-Series TopPure15B-E1
Pretreatment module
High pressure pump
Reverse osmosis
Dual wavelength UV-lamp
Ultra-purification cartridge
Ultrafiltration cartridge
EDI Module
Point-of-use filter
Storage tank 30L
Air filter net for tank
UV-lamp sterilizer for water tank
Remote water dispenser with color display
TOC monitoring module /
Specifications
Model TopPure15B-E1/E2
Feed Water Requirement
Source Tap water
Conductivity* <2000us/cm
Hardness** <450ppm as CaCO3
Pressure 0.05~0.5MPa(7-72psi)
Temperature 5~40℃
Purification Water(Class III)
Ionic Rejection >95%
Bacteria Rejection >99%
Conductivity 1~20us/cm
Productivity Rate 30L/h
High Quality Purification Water(Class II)
Resistivity At 25℃ 10MΩ.cm
TOC <30ppb
Dissolved Organic <0.1ppm
Productivity Rate 15L/h
Ultrapurification Water(Class I)
Resistivity At 25℃ 18.2MΩ.cm
Conductivity At 25℃ 0.055us/cm
TOC Level** 1~5ppb
Endotoxin(Pyrogens)**** <0.001EU/ml
Particulate(≥0.02µm) <1pc/ml
Bacteria* <0.1 cfu/ml
Rnase / Dnase** Free
Manual dispense flow rate 1.5~2.0L/min
Automatic dispense volume 100~60000ml
Electrical Requirements
Electrical Voltage 110V/220V±10%
Electrical Frequency 50HZ/60HZ
Packing Information
Net Weight
Main units 35kg
Water tank (30L) 7kg
External Dimensions(WxDxH)
Main units 315x525x570mm
Water tank (30L) 380x380x595mm
Shipping weight
Main units 37kg
Water tank (30L) 15kg
Shipping Dimensions(WxDxH)
Main units 525x610x770mm
Water tank (30L) 520x440x615mm
Introduction about laboratory water purification system

Advanced laboratory water purification systems operate with continuous monitoring to ensure consistent water quality. Resistivity or conductivity meters deliver instantaneous feedback on ionic content, and TOC sensors track levels of organic impurities. Equipped with data logging functions, these systems often support connectivity to lab networks, enabling remote oversight and instant notifications. This proactive surveillance guarantees the water consistently adheres to its designated purity specifications. Should quality fall below a predefined limit, the system can automatically stop distribution or send alerts to staff, thereby providing proactive protection against the use of non-compliant water in sensitive experimental procedures.

Send your inquiry
Please send us your request and we will reply to you as soon as possible.
Send