3 Deck Floor Laboratory Orbital Shaker Big Capacity 1000mlx168

Product Details

Place of Origin: China

Brand Name: Senova

Certification: CE

Model Number: DFS-904

Payment & Shipping Terms

Minimum Order Quantity: 1unit

Price: Available upon request

Packaging Details: plywood case

Delivery Time: 5-20 working days

Payment Terms: T/T

Supply Ability: 100 units

Get Best Price
Chat Now
Specifications
Highlight:

Floor Laboratory Orbital Shaker

,

3 Deck Laboratory Orbital Shaker

,

1000mlx168 Laboratory Shaker

Product:
Obital Shaker For Laboratory
Capacity:
1000mlx168, 500mlx324,250mlx450
Speed Range:
30~250rpm
Orbit:
50mm
Platform Size:
1080x680mm (6PCS)
Power Supply:
220V/50Hz, 220V/60Hz, 110V/60Hz
Product:
Obital Shaker For Laboratory
Capacity:
1000mlx168, 500mlx324,250mlx450
Speed Range:
30~250rpm
Orbit:
50mm
Platform Size:
1080x680mm (6PCS)
Power Supply:
220V/50Hz, 220V/60Hz, 110V/60Hz
Description
3 Deck Floor Laboratory Orbital Shaker Big Capacity 1000mlx168
Big Capacity 3-deck Floor Orbital Shaker DFS-904
Main Features
  1. Programmable P.I.D. control automates complex incubation sequences
  2. Industrial-grade steel construction ensures process reliability
  3. Interactive 7" touch screen centralizes all control parameters
  4. Precision servo motor technology provides reproducible shaking dynamics
  5. Multi-segment programming (30 steps) accommodates intricate protocols
  6. Self-regulating operation with automatic cycling and recovery features
  7. Memory function optimizes workflow by recalling previous parameters
  8. Continuous monitoring with dedicated safety alarms
  9. Equipment-isolating protection circuits prevent collateral damage
  10. High-performance alloy components resist wear and corrosion
  11. Premium bearing system minimizes vibration and noise
  12. Controlled acceleration prevents sample compromise during startup
  13. Fail-safe protection against thermal and control system failures
  14. Integrated emergency stop accessible during automated runs
  15. Scalable platform configurations (2-3 decks) match throughput needs
  16. Universal flask compatibility through adjustable clamps
  17. Digital data recording via optional USB connectivity
  18. Specialized rack options for automated sample handling
Technical Data
Control P.I.D.
Display LCD
Program Control 8 segments (user programmable)
Safety Protection Automatic stop and start, timing, time display, power-off recovery, parameter memory
Auxiliary Function Monitoring timer, Independent over-speed acoustic/visual alarm, independent current leakage and over-load protection
Convection Mode Natural Convection
Shaking Mode Orbital
Drive Single-shaft drive
Working Environment 15℃-35℃
Timing Range 0-999.59 hr/Continuous
Speed Range(rpm) 30-250
Speed Accuracy ±1rpm
Orbit Φ50mm
Capacity 1000mlx168, 500mlx324,250mlx450
Platform Size(mm) 1080x680
Platform Qty. 6
N.W./G.W. (Kg) 740/800
Overall Dimensions(LxWxH,mm) 1590x1120x1310
Packing List(LxWxH,cm) 164x117x138
Power 250W
Power Supply AC 200-240V/50-60Hz. Optional: AC110V/60Hz
Construction Powder Coated Steel Housing

3 Deck Floor Laboratory Orbital Shaker Big Capacity 1000mlx168 03 Deck Floor Laboratory Orbital Shaker Big Capacity 1000mlx168 13 Deck Floor Laboratory Orbital Shaker Big Capacity 1000mlx168 23 Deck Floor Laboratory Orbital Shaker Big Capacity 1000mlx168 3

Introduction about laboratory shaker

Laboratory shakers, ranging from space-saving benchtop units to high-capacity floor models, are engineered for consistent sample agitation. Their function is to mix, aerate, or suspend the contents of flasks, tubes, or plates through controlled mechanical motion. This action ensures the creation of homogeneous environments, which is a prerequisite for accuracy in applications like cell culture, protein studies, and diagnostic assay development.

The operational principle is based on imparting standardized kinetic energy to samples. This mechanizes a critical step that is difficult to control manually. The orbital shaker is the most common implementation. For protocols requiring environmental control, incubator shakers are employed. Modern versions are characterized by sophisticated user interfaces, often featuring color touchscreens, data logging capabilities, and programmable protocol sequences for complex, multi-day experiments.

Shakers are applied across diverse scientific activities. They are used for culturing insect cells for baculovirus expression systems. They assist in solubility and stability testing of new chemical entities. In clinical laboratories, they ensure consistent mixing of samples in blood culture bottles. Important design and performance features include a vibration-damped drive system for smooth operation, a range of available platform sizes and configurations, and safety interlocks to prevent operation when access doors are open.